How does proactive monitoring work?

How Power Monitor checks your environment continuously, how often, and how alerts reach you.

Power Monitor monitoring is continuous and automatic: you do not need to open the system to find out that something failed. Power Monitor queries your tenant through the official Microsoft APIs in regular cycles and, when it detects a problem, opens an incident and sends an alert to the configured recipients. When the problem is resolved, it sends the resolution notice.

What is checked, and how often?

Situation How it is detected Approximate frequency
Semantic model refresh failure Refresh history of the models on capacity, in all monitored workspaces Every 15 minutes
Fabric item failure (data pipeline, notebook, Copy job, Dataflow Gen2) Runs that end with failure or cancellation Every 2 hours
Gateway offline Status of each gateway on which the Power Monitor application is an administrator Every 5 minutes
Capacity usage limit Accumulated capacity usage, read from the Fabric Capacity Metrics app, equal to or above 80% Every 5 minutes
High background usage Background consumption by thresholds (50%, 70%, 80%, and 100%) Every 5 minutes
Consumption data unavailable No new capacity consumption data for more than 45 minutes (for example, paused capacity or metrics source unavailable) Every 5 minutes
Consumption anomaly by item An item's consumption above the baseline of the last 7 days Every 5 minutes
Execution time deviation (optional, per item) A run much longer than the item's average Every hour
Capacity cost Daily cost above the average of the last 30 days plus the configured percentage Daily
Capacity running outside business hours Capacity active outside the configured window Every 5 minutes
Data freshness and Fabric Mirroring Monitors configured per item (maximum data delay, mirroring state) Every 10 minutes

In addition to event alerts, there is the Daily Checklist (a daily summary of the environment) and the Hourly Checklist (sent only when there is an occurrence).

Only monitored workspaces generate refresh and Fabric item alerts. See Workspaces.

Which channels deliver the notifications?

The channels are configured by an administrator in Settings › Alerts:

  • Email, through the Power Monitor server or through an SMTP account of your own company;
  • Microsoft Teams, through the Power Monitor bot installed in the chosen team and channel;
  • Slack;
  • Telegram.

Can I choose which alerts to receive?

Yes. In Settings › Notifications, the administrator chooses which alert types each recipient receives and can Test the delivery. In addition:

  • users with a workspace scope receive only the alerts for the workspaces they are linked to (alerts without a workspace, such as gateways and capacities, go to all eligible recipients);
  • execution time deviation is enabled item by item;
  • the consumption floor for anomalies and the percentage of the cost alert are configurable.

Today Power Monitor does not have quiet hours (a window without notifications) or generic webhooks. The 80% threshold of the capacity usage alert is fixed.

What if the problem persists?

For gateways, semantic models, and Fabric items, the email is sent when the incident is opened and when it is resolved; recurrences while the incident is open are counted and appear in the Hourly Checklist. For the capacity usage limit, reminders continue while the situation persists. All alerts are recorded in Monitoring › Alerts.

Does monitoring work 24/7?

Yes. The checks run continuously, 24 hours a day, 7 days a week, including outside business hours.

Want our team to act on the alerts?

Power Tuning offers Managed Monitoring, in which our team acts on the critical alerts of your environment, with a 2-hour SLA for the first response.

Last updated